Workarounds and Limitations: Known issues in IBM Engineering Lifecycle Optimization – Publishing 7.0.3

The following known problems are related to this release.

Workarounds

The following problems in this release have workarounds:


Workarounds

PUB 7.0.3 is unable to access the data sources of ELM 7.0.2 applications


First occurrence
7.0.3

Problem
When a user tries to generate a document with IBM Engineering Lifecycle Optimization – Publishing (PUB) 7.0.3 using data sources from the Engineering Lifecycle Management (ELM) 7.0.2 applications, the document generation fails due to the TLS version mismatch.

Workaround
1.  Go to the PUB installation path (%rpe_home%).
2.  Open the rpe-studio.ini file in the studio folder and add the following flag:
    com.ibm.engineering.pub.strictTLSversion="TLSv1.2”

3. Open the rpe-launcher.ini file in the launcher folder and add the following flag:
    com.ibm.engineering.pub.strictTLSversion="TLSv1.2”
4.
Save the file.

Back to top


When Publishing Document Builder is configured with JTS authentication, the behavior of Engineering Test Management (ETM) and Engineering Workflow Management (EWM) is different from Engineering Requirements Management DOORS Next (DOORS Next) and Global Configuration Management (GCM)


First occurrence
7.0.3

Problem
If the Publishing Document Builder is configured with JTS authentication, the data source URLs use credentials or cookies from the session. Hence, if the username and password are not provided in the connection, the document is generated successfully.

The behavior of ETM and EWM is different from DOORS Next and GCM:
  – For DOORS Next and GCM, the delegated Resource selection dialog is directly opened. No authentication is required.
  – For EWM and ETM, instead of a delegated picker dialog, a link to log in is displayed. When you click the login link, a separate browser page opens for JTS authentication.

Workaround
1. Open Publishing Document Builder. Ensure that the Publishing Document Builder is configured with JTS authentication.
2. Add the connection.
3. Select the URL of the data source.
4. Select common providers and click Go.
5. Enter the username and password before you select the resource in the picker.

Back to top


Unable to update an older version of the PUB client to PUB 7.0.3 using the Installation Manager)


First occurrence
7.0.3

Problem
You are not able to use the update functionality in the Installation Manager to update an older version of the PUB client to PUB 7.0.3 due to the IES version upgrade.

Workaround
You can uninstall the older version of the PUB client from Installation Manager and install PUB 7.0.3 as a fresh install.

Back to top


Dashboards and work items are no longer publicly available, so some links may be invalid. We now provide similar information through other means. Learn more here.
Feedback
Was this information helpful? Yes No 0 people rated this as helpful.