Workarounds: Execution problems in Rational Quality Manager 4.0.3
Build basis: IBM® Rational® Quality Manager 4.0.3
The following known problems are related to execution in the Rational Quality Manager 4.0.3 release.
Workarounds
The following problems in this release have workarounds:
- Test plan execution summaries calculate the execution points for previous iterations
- Script execution halts if an automated keyword returns an INCOMPLETE execution result
- Machine name is not visible in the Adapter Console when the adapter is running on a Linux system
Limitations
The following problems in this release do not currently have workarounds:
Workaround summary
Test plan execution summaries calculate the execution points for previous iterations
Author: Vaibhav Srivastava
Last updated: 23 May 2013
Problem
The test plan execution summary shows points for all iterations instead of showing only the information about the current iteration.
Workaround
To view the points per iteration for current or past iterations, complete these steps:- From the Planning menu, click Browse Test Plans. On the page that opens, from the View As list, select Execution. In that view, the test plans are displayed as a list, and the overall execution points for all iterations are displayed.
- To see details about the progress and points for individual iterations, expand the row for the iteration.
Related information
Workaround summary
Script execution halts if an automated keyword returns an INCOMPLETE execution result
Author: Vaibhav Srivastava
Last updated: 23 May 2013
Problem
If you use an automation tool for keyword execution, even though the tool sends an INCOMPLETE or PARTIALLY_BLOCKED status, the keyword execution shows INCONCLUSIVE and BLOCKED states.Workaround
Keyword execution supports a limited set of execution result states that do not include INCOMPLETE and PARTIALLY_BLOCKED states. In the automation tool, use the INCONCLUSIVE state in place of the INCOMPLETE state, and use the BLOCKED state in place of the PARTIALLY_BLOCKED state.Related information
Workaround summary
Machine name is not visible in the Adapter Console when the adapter is running on a Linux system
Author: Vaibhav Srivastava
Last updated: 23 May 2013
Limitation summary
The Weight property in execution results and suite results cannot be modified
Author: Vaibhav Srivastava
Last updated: 23 May 2013
Problem
After an execution is completed, the overall weights in test case results and test suite results cannot be modified. Test case results inherit the weights of test case execution records, and test suite results inherit the weights of test suite execution records. Before you start the execution, if you update the weights of the execution records, the execution results will reflect the changes appropriately.